Verified Electrical & Mechanical Specifications
Product Overview & Dielectric Architecture
MKP-L Custom is a high-voltage DC-link module built around metallized polypropylene film, configured as a single cell, busbar module, or integrated EV DC-link assembly. The dielectric construction delivers low ESR and stable capacitance across a custom voltage window of 500V to 2000V DC, with representative builds such as 1400V DC 100µF and 2000V DC 118µF. Terminations include laminated copper busbar, M6/M8 studs, or custom tabs, so the module drops directly into traction inverter, on-board charger, and DC fast-charging bus structures.
Each module is a dry, self-healing design intended for continuous ripple current in EV main traction inverters, OBC circuits, high-power DC fast charging piles, and utility battery energy storage. The custom format lets OEM engineers match capacitance, voltage class, and terminal geometry to an existing busbar layout instead of redesigning around a catalog part. Reference standards are GB/T 17702 and IEC 61071.
Electrical Behavior & Compliance Standards
Electrically, MKP-L Custom behaves as a low-inductance DC-link element: laminated busbar terminals shorten the current path, which keeps loop inductance low and supports fast IGBT switching with controlled voltage overshoot. Metallized polypropylene gives a low dissipation factor and stable capacitance over the 500V to 2000V DC range, so ripple current is handled with modest self-heating. Self-healing clears local dielectric faults, and dry construction avoids liquid leakage risk in inverter enclosures.
Thermal design centers on ESR and hot-spot temperature; OEMs should derate for elevated ambient inside traction and charging cabinets and verify terminal torque at M6/M8 studs. Safety margins are validated through voltage-withstand and insulation testing during production. The series is referenced to GB/T 17702 and IEC 61071, which cover DC-link film capacitor testing and endurance expectations for power electronic applications.
Circuit Selection & Typical Applications
Sizing MKP-L Custom starts with the DC bus voltage and allowable ripple: pick a voltage class with margin above the maximum bus level, then choose capacitance from the permitted bus voltage ripple and the inverter's switching frequency. Confirm the RMS ripple current against ESR at the expected hot-spot temperature, and check that the module footprint and terminal pattern match the busbar.
- Define bus voltage and capacitance from ripple budget, not nameplate alone.
- Select single cell, busbar module, or integrated EV DC-link by mechanical envelope.
- Choose laminated copper busbar, M6/M8 studs, or custom tabs for the mating interface.
- Verify ESR and thermal derating for the enclosure ambient and duty cycle.
- Confirm clearance, creepage, and mounting torque before prototype release.
- EV Main Traction Inverters
- On-Board Chargers (OBC)
- High-Power DC Fast Charging Piles
- Utility Battery Energy Storage
OEM Manufacturing & Quality Screening
SMILER produces MKP-L Custom modules at its Foshan, Shunde facility, where 9 production lines and a 7-member QA/QC team support DC-link builds. Every unit passes 100% electrical screening, including DC withstand voltage testing and leak inspection, backed by an in-house laboratory. The 9-member engineering team and 20 patents support custom capacitance, voltage, housing, and terminal changes for OEM programs.
Prototyping is fast: the shortest sample lead time is 5 days, and average mass production delivery runs about 15 days. OEM customization covers private-label marking, terminal geometry, and module configuration, letting buyers move from busbar drawing to screened samples quickly.
Explore related industrial applications, browse our engineering selection guides, or request a MKP-L Custom datasheet and sample quote.
MKP-L Custom Frequently Asked Questions
What voltage and capacitance range can MKP-L Custom cover?
The custom voltage window runs from 500V to 2000V DC, with verified examples including 1400V DC 100µF and 2000V DC 118µF. Capacitance and voltage class are set per project, so OEMs should specify bus voltage, ripple budget, and mechanical envelope when requesting a quote.
Which terminal and module configurations are available for MKP-L Custom?
MKP-L Custom ships as a single cell, busbar module, or integrated EV DC-link assembly. Terminal options include laminated copper busbar, M6/M8 studs, and custom tabs. Selection depends on the mating busbar, mounting torque, and clearance requirements of the inverter or charger enclosure.
What are the sample and production lead times for MKP-L Custom?
The shortest prototyping lead time is 5 days, and average mass production lead time is 15 days. Samples are screened with DC withstand voltage and leak testing before shipment, so OEM engineers can validate electrical and mechanical fit before committing to volume orders.
Related Capacitor Series
Need Datasheets or Custom OEM Film Capacitors?
Send your capacitance, voltage rating, and mechanical drawing. Our 9-member engineering team replies within 24 hours with 5-day prototyping availability.